Narrow stile door applications with push pad operation and activated on signal from access control
system. Key override at all times on outside, push pad always operational from inside.
Operating voltage: 12 V dc or 24 V dc stabilised (+15%-10%)
Current draw: 12 V dc 480 mA max 24 V dc 240 mA max
Backsets available: Adjustable from 25 mm, 28 mm, 30 mm, 35 mm or 35 mm
Monitoring: Bolt position
EN179
when used with correct furniture
EN12209
EN61000-6-1